ReadTotalTimeoutConstant Property
A constant used to calculate the total time-out period for read operations, in milliseconds. For each read operation, this value is added to the product of the ReadTotalTimeoutMultiplier and the requested number of bytes.
Access
Read/Write
Syntax
Visual Basic |
ReadTotalTimeoutConstant As Long |
---|---|
Visual C++ (MFC) |
long get_ReadTotalTimeoutConstant(); void put_ReadTotalTimeoutConstant(long value); |
Visual C++ (#import) |
LONG ReadTotalTimeoutConstant; |
Remarks
A value of zero for both the ReadTotalTimeoutMultiplier and ReadTotalTimeoutConstant indicates that total time-outs are not used for read operations.
Errors
The property may throw exception. Use GetLastError method to get the error code.